Thanks will do, is there a way to schedule the disk consolidation during less busy times?
Re: VM disk consolidation
Re: clone vm error 503
its an appliance and the links are dead anyways
Re: All Flash - Deduplication and Compression
Sorry for the delay.
The current usage of the vSAN cluster is 72% and i have a total of 153 VMs and there are more to go in the next few weeks.
Another question:
Is there a way to see if a VM is currently been deduplicated? I mean to see the information of deduplication and compression individually.
Thanks in advance.
New Virtual on Samsung 860 EVO SSD
I am trying to create a new virtual machine using ESXI 6.5. When I click finished I get the error I have attached in the screenshot. I have used the following SCSI Controllers. LSI Logic SAS, LSI Logic Parallel, VMware Paravirtual. I am thinking I may need the driver for these SSDs. But I have found nothing online. Anyone with experience in this? I am at a dead end.
Re: you have ordered a dell system with no os installed
the OS disc is SCSi 0:0
physical use scsi
thanks
Re: import esxi image for upgrade via powercli
You can't upload an ESXi image to Update Manager afaik.
But you can upgrade an ESXi node with with an Offline Bundle and the Install-VMHostPatch cmdlet.
See for example https://www.virtualizationhowto.com/2017/08/update-vmware-esxi-6-0-6-5-powercli/
Re: you have ordered a dell system with no os installed
Re: you have ordered a dell system with no os installed
try repair windows
Re: 6.5 U2 upgrade to 6.7 - will there ever be a supported upgrade path
I understand that, but will it ever be? They cant just leave customers on 6.5 U2.
Re: 503 Service Unavailable (Failed to connect to endpoint: [class Vmacore::Http::NamedPipeServiceSpec:0000000000FAD020] _serverNamespace = / _isRedirect = false _pipeName =\\.\pipe\vmware-vpxd-webserver-pipe)
Take snapshot of vcenter and try this
Stop all vcenter services using service-control --stop --all
Check "C:\ProgramData\VMware\vCenterServer\data\vpostgres\postmaster.pid" file - if exist delete the file or move it to another location
Reboot the vCenter
Re: 503 Service Unavailable (Failed to connect to endpoint: [class Vmacore::Http::NamedPipeServiceSpec:0000000000FAD020] _serverNamespace = / _isRedirect = false _pipeName =\\.\pipe\vmware-vpxd-webserver-pipe)
Also check if the vCenter has space issue where the postgres is residing like C drive nearing space .. It needs to have 10% space available minimum
Re: 6.5 U2 upgrade to 6.7 - will there ever be a supported upgrade path
There will be definitely in future for sure. This is the same happened for 6.0 U3 to 6.5.
You can refer this in future
VMware Product Interoperability Matrices
VMware will release the compatibility path however none has ETA for now.
Thanks,
MS
HTML plugin: sampleB breaks when replacing urn:cr with abc:xyz
I had a problem for a few days, where I was not able to add options to custom objects and I managed to reproduce it on one of the samples:
If you replace "urn:cr" with "abc:xyz" in the bundle-context.xml of the service as well as in the ModelObjectUriResolver (replace SCHEME with "abc" and NAMESPACE with "xyz"), then a right click on a Chassis in the view won't show any menu items.
This looks like a bug on the vSphere SDK side.
Re: Threadripper ESXi 6.7 GPU and USB passthrough, experience progress and problems
4 GPU passthrough devices, 2 USB controllers, 1 audio device, split amongs 4 VM's.
Using only motherboard USB now. Seems to work with d3d0; would you suggest changing it to something else?
Also, I'm getting random VM lockups when under GPU load (not often, on the order of once in a few hours.) VM locks hard, host is OK, but rebooting the vm puts it into Error 43 with no gpu: need to reboot the host to fix this. The VM with the GPU furthest on the motherboard from the CPU is most often affected. Don't know if this is a pciHole, msiEnable, or agesa problem... grrr.
I looked into the log files when rebooting the VM (into error 43). "Bad" reboots have this at the end: (truncated). There's some earlier stuff about vmware tools not loading either. Anyone know that this stuff means? (This text doesn't appear on normal boots, only after a lockup that yields error 43 on VM reboot).
Thanks LT
2018-07-05T21:49:31.734Z| vcpu-2| I125: Guest MSR write (0x49: 0x1)
2018-07-05T21:49:31.734Z| vcpu-4| I125: Guest MSR write (0x49: 0x1)
2018-07-05T21:49:31.734Z| vcpu-6| I125: Guest MSR write (0x49: 0x1)
2018-07-05T21:49:31.734Z| vcpu-3| I125: Guest MSR write (0x49: 0x1)
2018-07-05T21:49:31.734Z| vcpu-0| I125: Guest MSR write (0x49: 0x1)
2018-07-05T21:49:31.734Z| vcpu-5| I125: Guest MSR write (0x49: 0x1)
2018-07-05T21:49:32.836Z| svga| I125: SVGA disabling SVGA
2018-07-05T21:49:33.277Z| vcpu-7| I125: LSI: Invalid PageType [21] pageNo 0 Action 0
2018-07-05T21:49:43.510Z| vcpu-0| I125: Destroying virtual dev for scsi0:0 vscsi=8197
2018-07-05T21:49:43.510Z| vcpu-0| I125: VMMon_VSCSIStopVports: No such target on adapter
2018-07-05T21:49:43.511Z| vcpu-0| I125: DEVICE: Resetting device 'ALL'.
2018-07-05T21:49:43.511Z| vcpu-0| I125: USB: Per-Device Resetting device 0x200000050e0f0003
2018-07-05T21:49:43.511Z| vcpu-0| I125: Tools: ToolsRunningStatus_Reset, delayedRequest is 0x91DA8A4270
2018-07-05T21:49:43.511Z| vcpu-0| I125: Tools: Changing running status: 1 => 0.
2018-07-05T21:49:43.511Z| vcpu-0| I125: GuestLib Generated SessionId 11821741703570650877
2018-07-05T21:49:43.511Z| vcpu-0| I125: Checkpoint_Unstun: vm stopped for 3527 us
2018-07-05T21:49:43.511Z| vcpu-0| I125: CPU reset: hard (mode 0)
2018-07-05T21:49:43.512Z| vcpu-1| I125: CPU reset: hard (mode 0)
2018-07-05T21:49:43.512Z| vcpu-2| I125: CPU reset: hard (mode 0)
2018-07-05T21:49:43.512Z| vcpu-3| I125: CPU reset: hard (mode 0)
2018-07-05T21:49:43.512Z| vcpu-7| I125: CPU reset: hard (mode 0)
2018-07-05T21:49:43.512Z| vcpu-6| I125: CPU reset: hard (mode 0)
2018-07-05T21:49:43.512Z| vcpu-5| I125: CPU reset: hard (mode 0)
2018-07-05T21:49:43.512Z| vcpu-4| I125: CPU reset: hard (mode 0)
2018-07-05T21:49:43.518Z| vcpu-0| I125: SVGA: Unregistering IOSpace at 0x1070
2018-07-05T21:49:43.518Z| vcpu-0| I125: SVGA: Unregistering MemSpace at 0xe8000000(0xe8000000) and 0xfe000000(0xfe000000)
2018-07-05T21:49:43.519Z| vcpu-0| I125: SCSI: switching scsi0 to push completion mode
2018-07-05T21:49:43.519Z| vcpu-0| I125: Creating virtual dev for 'scsi0:0'.
2018-07-05T21:49:43.519Z| vcpu-0| I125: DumpDiskInfo: scsi0:0 createType=11, capacity = 536870912, numLinks = 1, allocationType = 2
2018-07-05T21:49:43.519Z| vcpu-0| I125: SCSIDiskESXPopulateVDevDesc: Using FS backend
2018-07-05T21:49:43.519Z| vcpu-0| I125: DISKUTIL: scsi0:0 : geometry=33418/255/63
2018-07-05T21:49:43.519Z| vcpu-0| I125: SCSIFilterESXAttachCBRCInt: CBRC not enabled or opened without filters,skipping CBRC filter attach.
2018-07-05T21:49:43.519Z| vcpu-0| I125: SCSIFilterSBDAttachCBRC: device scsi0:0 is not SBD. Skipping CBRC attach SBD way.
2018-07-05T21:49:43.567Z| vcpu-0| I125: PCIXHCI: Interrupt type changed from MSIX to INTX
2018-07-05T21:49:43.578Z| vcpu-0| I125: PCIBridge4: ISA/VGA decoding enabled (ctrl 0004)
2018-07-05T21:49:43.578Z| vcpu-0| I125: pciBridge4:1: ISA/VGA decoding enabled (ctrl 0004)
Re: Memory DIMMs DELL server
You should order "OpenManage Integration for VMware vCenter" formaly known as "Dell Managment Plugin for VMware vCenter" which adds your PowerEdge Inventory into vCenter so you can see it on cluster or host level. Its available since 2010 or so. It show support lifetime also and as a major plus you can apply FW updates to the hosts through WebClient.
Regards,
Joerg
Starting Vmware Workstation 14x
On attempt to start VMware,
VMware Kernel Module Updater
is automatically loaded and
Before you can run VMware, several modules must be compiled and loaded into the running kernel.
is displayed with options to either `Cancel` or `Install`.
However, when I attempt to install them, the dialogue just disappears.
I've attempted to manually configure the `VMware Tools kernel modules` with
vmware-config-tools.pl --modules-only
in the terminal and nothing has been successful. The following line;
Gtk-Message: 23:51:38.574: GtkDialog mapped without a transient parent. This is discouraged.
Gtk-Message: 23:51:46.240: GtkDialog mapped without a transient parent. This is discouraged.
are printed at the end of the command. I'm stuck and I don't think I know how to fix this.
I believe this caused by the `Ubuntu kernel version upgrade` I made earlier this week.
Re: missing /vmfs/volumes/ after loss of power
> It seems that the datastore was on a iSCSI Software Adapter and its location is (was) on a separate NAS, which was damaged for a short time after the loss of power due to an overvoltage.
> This NAS is mounted via NFS and a search for my VM files on the NAS with user root returned no results!
If your datastore was using VMFS via iSCSI before then the NFS-server will not display the VMs when you use it via NFS.
Try to connect it via iSCSI again.
Re: Invalid Snapshot Configuration
One typical reason for this error message is a VM that has been created by Workstation and has not been correctly imported.
Please provide more details - such as the vmdk-descriptorfile and the vmware.log
Re: Invalid Snapshot Configuration
Re: you have ordered a dell system with no os installed
Looks like Converter included the Dell recovery partition.
Boot the VM with a LiveCD of your choice and check if the Windows boot partition is present and if the boot-flag is set correctly.